![DL/T5210.6-2009电力建设施工质量验收及评价规程第6部分:水处理剂制氢设备和系统(英文版)](https://wfqqreader-1252317822.image.myqcloud.com/cover/814/33688814/b_33688814.jpg)
4.5 Sea Water Desalination System
4.5.1 Installation of evaporator equipment supports.
1 Scope of application:low temperature multi-effect evaporation equipment,multi-stage flashing equipment.
2 Inspection quantity:check them one by one.
3 Quality standards and inspection methods are as shown in Table 4.5.1.
Table 4.5.1 Installation of evaporator equipment supports
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_156.jpg?sign=1739298989-LjatCIiVoRRpYttUPCp3WzLGBhWPmXQ3-0-e84e9a1e902cd618d3dbb171f0444c70)
4.5.2 Installation of evaporators.
1 Scope of application:low temperature multi-effect evaporation equipment,multi-stage flash equipment.
2 Inspection quantity:check them one by one.
3 Quality standards and inspection methods are as shown in Table 4.5.2.
Table 4.5.2 Installation of evaporators
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_157.jpg?sign=1739298989-MqOWx90pVaS2WBTnGoGoYpK6ki6IUKol-0-ad667678db27fd1a8bf22ff1a7bad075)
4.5.3 Installation of thermal compression ejectors.
1 Scope of application:equipment for completing low temperature multi-effect evaporators.
2 Inspection quantity:check them one by one.
3 Quality standards and inspection methods are as shown in Table 4.5.3.
Table 4.5.3 Installation of thermal compression ejectors
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_158.jpg?sign=1739298989-IKhCuHHT4n2XinQWnM5ZwT4NUvAR5pX9-0-924d924806e50d207d7f88771186ec10)
4.5.4 Installation of energy recovery devices.
1 Scope of application:reverse osmosis completing devices.
2 Inspection quantity:check them one by one.
3 Quality standards and inspection methods are as shown in Table 4.5.4.
Table 4.5.4 Installation of energy recovery devices
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_159.jpg?sign=1739298989-rs9phypF8s5T4uTkuZEIsorpCKgP0nNM-0-9d3b4fc68a1973426a03856284256723)
4.5.5 Installation of automatic self-cleaning filters.
1 Scope of application:water treatment system.
2 Inspection quantity:check them one by one.
3 Quality standards and inspection methods are as shown in Table 4.5.5.
Table 4.5.5 Installation of automatic self-cleaning filters
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_160.jpg?sign=1739298989-9memS6N56QKtnmDAhoLhLA1zgE4fkWtx-0-20cae01db5855838f8f89f533ecdd02a)
4.5.6 Installation of vacuum degasser.
1 Scope of application:sea water desalination and demineralization system.
2 Inspection quantity:check them one by one.
3 Quality standards and inspection methods are as shown in Table 4.5.6.
Table 4.5.6 Installation of vacuum degasser
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_161.jpg?sign=1739298989-vqPLN5IVowhCQSZgOfK6ySeDVNQE1dm1-0-94ec30e5f6570ee664234df25a16d71c)
Table 4.5.6(Continued)
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_162.jpg?sign=1739298989-7HN2MHCEcM252KmGm6yD2c0SoAqfgRgo-0-e872b54df7f249537f74238fa4c13761)
4.5.7 Installation of atmospheric carbon dioxide removal device.
1 Scope of application:sea water desalination and demineralization system.
2 Inspection quantity:check them one by one.
3 Quality standards and inspection methods are as shown in Table 4.5.7.
Table 4.5.7 Installation of atmospheric carbon dioxide removal device
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_163.jpg?sign=1739298989-U7xiu3VhY9x6rBrCYceoQHK7QKAxac46-0-bc7ac4b94fae6d0ea2e9854536e049ad)
Table 4.5.7(Continued)
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_164.jpg?sign=1739298989-X1lfCaTHkF41AUnZsXe4vQYtfuavgjSn-0-6468f3621d787666201cc3701ed8a27d)
4.5.8 Installation of cleaning devices.
1 Scope of application:water treatment system cleaning equipment.
2 Inspection quantity:check them one by one.
3 Quality standards and inspection methods are as shown in Table 4.5.8.
Table 4.5.8 Installation of cleaning devices
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_165.jpg?sign=1739298989-MscdiLqHmpyRM4z8I6aNjCk1ymP0Anwd-0-5cc2fcb017f6d85ac94ec1ef725060bd)
Table 4.5.8(Continued)
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_166.jpg?sign=1739298989-AvJjZGJpTpv8S3gFiqfvJW8jMPXjHAbg-0-d3baf939d9e88ca8482ad5e8e9d07a51)
4.5.9 Inspection of the compulsory provision implementation of the seawater desalination system shall conform to Table 4.5.9.
Table 4.5.9 Inspection table of compulsory provision implementation of the seawater desalination system
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_167.jpg?sign=1739298989-ZqZotVQv7jdMrBErXm8WaI78BgJJUwNe-0-082d37fc253d20355d0ba1abb920c2f6)
Table 4.5.9(Continued)
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_168.jpg?sign=1739298989-y3qcaknZP4TMyVd1Jq9e9LNiWthy3AAU-0-7e02a958c7cf866e12b5c5dd57f3d9dd)